Vista de pagina 63
LSI Corporation
- 64 -
6Gb/s MegaRAID SAS RAID Controllers User Guide
August 2012
Chapter 3: MegaRAID SAS RAID Controller Characteristics
6Gb/s MegaRAID SAS RAID Controller Family
Figure 24 Layout of the MegaRAID SAS 9286-8e RAID Controller
The following table describes the jumpers and the connectors on the MegaRAID SAS 9286-8e RAID controller.
NOTE Pin 1 on the headers and connectors is highlighted in red in the previous figure.
Table 18 MegaRAID SAS 9286-8e RAID Controller – Connectors
Jumper/
Connector
Type Description
J1A1 Write-Pending LED header 2-pin connector
Connects to an LED that indicates when the data in the
cache has yet to be written to the storage devices. Used
when the write-back feature is enabled.
J1A2 Global Drive Fault LED header 2-pin connector
Connects to an LED that indicates whether a drive is in a
fault condition.
J1A3 x4 SAS Ports 4 to 7 External connector SFF-8088 x4 external mini SAS connector
Connects the controller by cable to SAS drives or SATA drives.
J1B1 x4 SAS Ports 0 to 3 External connector SFF-8088 x4 external mini SAS connector
Connects the controller by cable to SAS drives or SATA drives.
85082-00
J1A1
J1A2
J2A1
J2A3
J4A1 J4A2 J5A2 J6A1
J2A2
J2B1
J1A3
J1B1