Configuring Units
114 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
Figure 55. Read Cache policy on the Controller Settings page
After you change the selection, the page refreshes, and a message at the
top confirms the change you have made.
To change the Read Cache unit policy In 3BM
1 At the main 3BM screen, select the unit by highlighting it and pressing
Enter.
An asterisk appears, indicating that the RAID unit is selected.
2
Tab to the Maintain Unit button and press Enter.
3 On the pop-up menu, select
Configure and press Enter.
4 In the Configure Disk Array screen,
Tab to the field Read Cache
Setting
.
The current setting—Intelligent, Basic, or Disabled—is shown.