LSI 3ware SAS 9750-8i Guía de usuario Pagina 276

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 342
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 275
Troubleshooting
264 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
0027 DCB checksum error detected
Event Type
Error
Cause
The drive’s Drive Configuration Block (DCB) has been corrupted.
The 3ware RAID controller stores certain configuration parameters on a
reserved area of each disk drive called the Drive Configuration Block. As part
of power-on initialization, the 3ware RAID controller performs a checksum of
the DCB area to ensure consistency.
Action
If this error occurs, please contact 3ware technical support at
http://www.lsi.com/channel/ContactUs for assistance.
0028 DCB version unsupported
Event Type
Error
Cause
The unit that is connected to your 3ware RAID controller was created on a
legacy 3ware product that is incompatible with your new controller.
During the evolution of the 3ware product line, the format of the Drive
Configuration Block (DCB) has been changed to accommodate new features.
The DCB format expected by the 3ware RAID controller and the DCB that is
written on the drive must be compatible. If they are not, this message is sent.
Action
Return the drives back to their original controller and contact 3ware technical
support at http://www.lsi.com/channel/ContactUs for further assistance.
Vista de pagina 275
1 2 ... 271 272 273 274 275 276 277 278 279 280 281 ... 341 342

Comentarios a estos manuales

Vikivzn 04 Jan 2024 | 17:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 01:42:43

Med

Renatimzn 07 Jan 2024 | 09:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 11:36:21

coin

Davidefb 11 Jan 2024 | 11:24:30

coin

Viktorijsw 11 Jan 2024 | 19:38:33

Cinema