LSI 9690SA-8E-KIT Guía de instalación Pagina 43

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 138
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 42
Controller Object Commands
www.lsi.com/channel/products 35
3. Smallest usable failed drive.
If the policy is disabled, only spare drives are used for an automatic rebuild
operation.
Example:
//localhost> /c0 show autorebuild
/c0 Auto-Rebuild Policy = on
/cx show bios
The /cx show bios command shows the BIOS version of controller /cx.
Example:
//localhost> /c0 show bios
/c0 BIOS Version = BG9X 2.x
/cx show carvesize
The /cx show carvesize command shows the maximum size of the volumes
that can be created if the autocarve policy is set to on. You can set the
carvesize between 1024 GB and 32768 GB (1 TB to 32 TB). Default
carvesize is 2048 GB (2 TB). For more information see, “/cx show autocarve”
on page 34.
Example:
//localhost> /c0 show carvesize
/c0 Autocarving Size = 2000 GB
/cx show ctlbus
The /cx show ctlbus command shows the controller host bus type, bus speed,
and bus width.
Example for 9690SA:
//localhost> /c2 show ctlbus
/c2 Controller Bus Type = PCIe
/c2 Controller Bus Width = 8 lanes
/c2 Controller Bus Speed = 2.5 Gbps/lane
/cx show driver
The /cx show driver command shows the device driver version associated
with controller
/cx.
Example:
//localhost> /c0 show driver
/c0 Driver Version = 3.x